DT type ozone discharge chamber


We have a complete production process, from the production of the AT electrode of the ozone generating unit, the manufacturing of the ozone generating room, the high-frequency power supply, the manufacturing of the high-voltage transformer, and the installation of the electrical control cabinet are all completed in the factory

Keywords: high-voltage transformer | electrical control cabinet | ozone generator

  • Product description
  • Function Description
    • Commodity name: DT type ozone discharge chamber

    1. As shown in the figure, the ozone discharge chamber according to the enamel tube, the output is: air source 0-30KG/h, ozone concentration 20-35mg/l, oxygen source 0-50KG/h, ozone concentration 120- 148mg/l.

    2. The enamel tube we selected has undergone a 12KV voltage suppression test, and a 6KV voltage discharge test in five minutes.

    3. The surface of the enamel tube is wrapped with high-insulation Teflon tape to effectively ensure the uniformity of the discharge gap. At the same time, it provides good convenience for maintenance.

    4. We try to integrate the water pump and the plate changer on the base of the discharge chamber to reduce the space occupation.

    5. For the different cooling water quality of the owner, we recommend a closed-circuit cooling water system to isolate the cooling water inside the discharge chamber from the cooling water of the external owner, so as to protect the discharge chamber, extend the maintenance cycle of the discharge chamber, and reduce maintenance costs.

    6. The discharge chamber pipeline is equipped with various instruments: temperature transmitter, pressure transmitter, metal float flowmeter, electromagnetic flowmeter, electric control valve and pneumatic control valve, ozone concentration detector, etc. The above instruments are controlled and displayed by the ozone control cabinet.

    4. The discharge chamber is welded with δ=3mm thick SS304 or SS316L plates, which meet the HG20592-2009 flange standard and GBT 17395-2008 steel pipe standard materials, and are welded to install GB/T985.1-2008 Standard implementation. The screws and nuts used meet the requirements of the national standard.

  • Ozone generator model Ozone production (Kg/h) Ozone concentration (g/m³) Air volume (Nm³/h) Cooling water volume (m³/h) Ozone power consumption (KWh/KgO₃)
    KCF-DT1.5 1.5 25~40 38~60 4~6 14~17
    KCF-DT2.0 2.0  25~40 50~80 6~8 14~17
    KCF-DT2.5 2.5 25~40 62~100 5~10 14~17
    KCF-DT3.0 3.0  25~40 75~120 9~12 14~17
    KCF-DT4.0 4.0  25~40 100~160 12~16 14~17
    KCF-DT5.0 5.0  25~40 125~200 15~20 14~17
    KCF-DT6.0 6.0  25~40 150~240 18~24 14~17
    KCF-DT8.0 8.0  25~40 200~320 24~32 14~17
    KCF-DT10.0 10.0  25~40 250~400 30~40 14~17
    KCF-DT12.0 12.0  25~40 300~480 36~48 14~17
    KCF-DT15.0 15.0  25~40 375~600 45~60 14~17
    KCF-DT20.0 20.0  25~40 500~800 60~80 14~17
    KCF-DT30.0 30.0  25~40 750~1200 100~120 14~17
    KCF-DT40.0 40.0  25~40 1000~1600 120~160 14~17
    KCF-DT50.0 50.0  25~40 1250~2000 150~200 14~17

     

    Model Ozone generating room Power cabinet
    Piping interface length x width x height mm Weight
    kg
    length x width x height mm Weight
    kg
    Air path Cooling water
    KCF-DT2.0 DN25 DN50 2300*1150*1500 1000 1000*800*1900 500
    KCF-DT2.5 DN25 DN50 2300*1150*1500 1100 1000*800*1900 550
    KCF-DT3.0 DN25 DN50 2900*1150*1500 1300 1000*800*1900 600
    KCF-DT4.0 DN25 DN50 2500*1350*1700 1400 2500*800*1900 800
    KCF-DT5.0 DN25 DN50 3200*1350*1700 1800 2500*800*1900 900
    KCF-DT6.0 DN50 DN65 3200*1400*1750 2000 2500*800*1900 1000
    KCF-DT8.0 DN50 DN65 3300*1560*1850 2300 2500*800*1900 1100
    KCF-DT10.0 DN50 DN65 3300*1560*1850 2500 2500*800*1900 1200
    KCF-DT12.0 DN50 DN65 3300*1560*1850 3200 3000*1000*2000 1600
    KCF-DT15.0 DN50 DN80 3450*1700*1950 3800 3000*1000*2000 1800
    KCF-DT20.0 DN50 DN80 3600*1800*2200 4800 3600*1100*2100 2200
    KCF-DT25.0 DN50 DN100 3600*1800*2200 5500 3600*1100*2100 2400
    KCF-DT30.0 DN65 DN100 4600*2200*2500 7200 3600*1100*2100 2800
    KCF-DT40.0 DN65 DN125 4700*2200*2500 9500 4800*1100*2200 2900
    KCF-DT50.0 DN80 DN150 4700*2200*2500 11500 4800*1100*2200 3100
    KCF-DT60.0 DN80 DN150 5000*2600*2800 14000 4800*1100*2200 3250
    KCF-DT80.0 DN100 DT200 5000*3000*2800 18000 9600*1200*2200 4000
    KCF-DT100.0 DN125 DN200 6000*3500*3000 20000 9600*1200*2200 4500

     

    Model Ozone generating room Power cabinet
    Piping interface length x width x height mm Weight
    kg
    length x width x height mm Weight
    kg
    Air path Cooling water
    KCF-DT1.0 DN50 DN50 2300*1150*1500 1500 1000*800*1900 400
    KCF-DT1.5 DN50 DN50 2900*1150*1500 1800 1000*800*1900 400
    KCF-DT2.0 DN50 DN50 2500*1350*1700 3000 2500*800*1900 500
    KCF-DT2.5 DN50 DN50 3200*1350*1700 3400 2500*800*1900 550
    KCF-DT3.0 DN50 DN65 3200*1400*1750 3600 2500*800*1900 600
    KCF-DT4.0 DN50 DN65 3200*1400*1750 4000 2500*800*1900 800
    KCF-DT5.0 DN50 DN65 3300*1560*1850 4200 2500*800*1900 900
    KCF-DT6.0 DN50 DN65 3300*1560*1850 4500 2500*800*1900 1000
    KCF-DT7.0 DN50 DN80 3450*1700*1950 4800 3000*1000*2000 1000
    KCF-DT8.0 DN50 DN80 3450*1700*1950 5250 3000*1000*2000 1100
    KCF-DT10.0 DN50 DN80 3500*1750*2100 5800 3000*1000*2000 1200
    KCF-DT12.0 DN65 DN100 3600*1800*2200 6000 3600*1000*2100 1600
    KCF-DT15.0 DN65 DN100 3600*1800*2200 6200 3600*1000*2100 1800
    KCF-DT20.0 DN80 DN125 4600*2200*2500 7000 4200*1100*2200 2200
    KCF-DT25.0 DN80 DN125 4600*2200*2500 8000 4200*1100*2200 2400
    KCF-DT30.0 DN100 DN150 4700*2200*2500 8800 4800*1100*2200 2800
    KCF-DT40.0 DN100 DN150 6000*2250*2800 10000 6000*1100*2200 2900
    KCF-DT50.0 DN150 DN200 6000*3500*3000 11000 7200*1200*2300 3100

     